Inspection
1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the PCSV connector.
|
3. |
Measure resistance between the PCSV terminals 1 and 2.
|
4. |
Check that the resistance is within the specification.
|
Removal
1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
2. |
Disconnect the purge control solenoid valve connector (A).
|
3. |
Disconnect the vapor hoses (B) from the purge control solenoid
valve.
|
4. |
Remove the valve after removing the bolt (C).
|
Installation
|
|
1. |
Installation is reverse of removal.
|
Description and Operation
Description
The starting system includes the battery, starter, solenoid switch, ignition
switch, inhibitor switch (A/T), ignition lock switch, connection wires and the
battery cable.
Whe ...
Heated Oxygen Sensor (HO2S). Schematic Diagrams
Circuit Diagram
...
Technical Data
System voltage: DC 12 V Working voltage: DC 10 - 15 V Amperage rating: max.
15 A Suitable for use at temperatures: -22 ~ +158°F (-30 ~ +70°C) Max. working
pressure: 6 bar (87 psi) Size Compresso ...