Hyundai Veloster: Purge Control Solenoid Valve (PCSV). Repair procedures
Inspection
| 1. |
Turn the ignition switch OFF.
|
| 2. |
Disconnect the PCSV connector.
|
| 3. |
Measure resistance between the PCSV terminals 1 and 2.
|
| 4. |
Check that the resistance is within the specification.
|
Removal
| 1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
| 2. |
Disconnect the purge control solenoid valve connector (A).
|
| 3. |
Disconnect the vapor hoses (B) from the purge control solenoid
valve.
|
| 4. |
Remove the valve after removing the bolt (C).
|
Installation
|
|
| 1. |
Installation is reverse of removal.
|
Purge Control Solenoid Valve (PCSV). Schematic Diagrams
CVVT Oil Control Valve (OCV). Description and OperationKey operations